Share:

SR 0502 TR 502 over SPRING BROOK

Map

Coordinates:
+41.35094, -75.71336
41°21'03" N, 75°42'48" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 0502 TR 502 over SPRING BROOK
Structure number:000000000020637
Old structure number:350502003014930 (from 1992 edition)
Location:MOOSIC BORO .8 M E TR 11
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:85.0 ft. [25.9 m]
Total length:180.1 ft. [54.9 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:48.9 ft. [14.9 m]
Skew angle:60°
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:6,191 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:92.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016FairSatisfactoryGoodGood619192.3
June 2014FairSatisfactoryGoodGood552192.8
June 2012FairSatisfactoryGoodGood558492.8
June 2010GoodGoodGoodGood557992.8
July 2008FairSatisfactoryGoodGood671891.9
June 2006FairFairGoodGood656991.0
June 2004FairSatisfactoryGoodGood709691.6
July 2002FairSatisfactoryGoodGood692992.7
August 2000FairFairGoodGood679390.8
October 1998FairSatisfactoryGoodGood618694.3
February 1997FairSatisfactoryGoodGood586493.5
March 1995GoodGoodGoodGood572193.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,3601,358200
Steel Protective Coatingsq. ft.21,50621,506000
Deck
Reinforced Concrete Decksq. ft.8,8208,29152900
Wearing Surfacessq. ft.7,2006,76843200
Substructure
Reinforced Concrete Pier Walllinear ft.9589510
Reinforced Concrete Abutmentlinear ft.216207810
Joints
Strip Seal Jointlinear ft.196196000
Bearings
Movable Bearingeach1616000
Steel Protective Coatingsq. ft.21,50621,506000
Fixed Bearingeach88000
Steel Protective Coatingsq. ft.10,75310,753000
Bridge Rail
Other Material Bridge Raillinear ft.3603501000