Share:

LAKEWOOD RD over HOTTENBAUGH RUN

Map

Coordinates:
+41.04046, -80.30021
41°02'26" N, 80°18'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LAKEWOOD RD over HOTTENBAUGH RUN
Structure number:000000000022514
Old structure number:377202046470080 (from 1992 edition)
Location:037008 HICKORY TOWNSHIP
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:49.9 ft. [15.2 m]
Total length:55.1 ft. [16.8 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:24.9 ft. [7.6 m]
Owner:County Highway Agency [02]
Year built:1955
Year reconstructed:2001
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2015

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:100 [as of 2005]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection has failed. River control devices have been destroyed. Stream bed aggradation, degradation or lateral movement has changed the channel to now threaten the bridge and/or approach roadway. [3]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:49.0 tons [44.5 metric tons]
Inventory rating:28.9 tons [26.3 metric tons]
Sufficiency rating:66.1
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
July 201566.1PoorGoodGoodPoorSD100
July 201366.1PoorGoodGoodPoorSD100
July 201166.1PoorGoodGoodPoorSD100
July 200965.1PoorGoodGoodPoor-100
July 200767.1PoorGoodGoodPoor-100
May 200566.8PoorGoodGoodPoor-100
May 200382.8FairVery GoodGoodFair-100
May 200167.0PoorPoorSatisfactoryPoorSD100
May 199967.0PoorPoorGoodPoorSD100
March 199769.0PoorFairGoodPoorSD100
May 199585.0FairFairGoodFair-100
April 199381.8FairGoodVery GoodFair-100
April 199192.8GoodGoodVery GoodGood-100