Share:

SR 0011 TR 11 over SHICKSHINNEY CREEK

Map

Coordinates:
+41.15255, -76.15064
41°09'09" N, 76°09'02" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 0011 TR 11 over SHICKSHINNEY CREEK
Structure number:000000000023599
Old structure number:400011020025070 (from 1992 edition)
Location:SHICKSHINNY BO JCT TR 239
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:41.0 ft. [12.5 m]
Total length:42.0 ft. [12.8 m]
Roadway width between curbs:40.4 ft. [12.3 m]
Deck width edge-to-edge:60.4 ft. [18.4 m]
Owner:State Highway Agency [01]
Year built:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Other [9]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,476 [as of 2016]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:67.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2017FairFairFairSatisfactory947667.0
January 2015FairSatisfactoryGoodSatisfactory876679.0
January 2013FairSatisfactoryGoodSatisfactory882677.1
January 2011FairSatisfactoryGoodSatisfactory875977.1
January 2009FairSatisfactoryGoodSatisfactory875977.1
January 2007FairSatisfactoryGoodSatisfactory871577.1
January 2005FairSatisfactoryGoodSatisfactory1111576.9
March 2003FairSatisfactoryGoodSatisfactory1081079.9
March 2001FairSatisfactoryGoodSatisfactory1148484.0
April 1999FairGoodGoodSatisfactory1125968.0
July 1997GoodGoodGoodGood1082268.0
August 1995FairSatisfactoryGoodSatisfactory1303068.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.567567000
Deck
Reinforced Concrete Decksq. ft.2,5652,565000
Wearing Surfacessq. ft.1,6801,680000
Substructure
Reinforced Concrete Abutmentlinear ft.121119200
Joints
Pourable Jointlinear ft.122122000
Bearings
Elastomeric Bearingeach2828000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.8484000
Steel Protective Coatingsq. ft.10,75310,753000