SR 0309 TR 309 over BIG BLACK CREEK
Map
Coordinates:
+40.97732, -75.9791640°58'38" N, 75°58'45" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 0309 TR 309 over BIG BLACK CREEK |
Structure number: | 000000000023847 |
Old structure number: | 400309015000000 (from 1992 edition) |
Location: | HAZLE TWP .1 M N TR 940 |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 25.9 ft. [7.9 m] |
Total length: | 26.9 ft. [8.2 m] |
Roadway width between curbs: | 56.4 ft. [17.2 m] |
Deck width edge-to-edge: | 64.6 ft. [19.7 m] |
Skew angle: | 20° |
Owner: | State Highway Agency [01] |
Year built: | 1928 |
Year reconstructed: | 1991 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Concrete [1] |
Main span design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: January 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 13,540 [as of 2017] |
Truck traffic: | 4% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 58.7 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $218,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
January 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 13540 | 58.7 |
January 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 12938 | 61.1 |
January 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 12938 | 61.1 |
January 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 8146 | 64.4 |
January 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 8114 | 64.4 |
January 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 20419 | 55.9 |
February 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 20177 | 55.7 |
February 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 23108 | 54.9 |
February 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 22456 | 50.2 |
April 1999 | Good | Good | Good | Good | 22456 | 53.2 |
June 1997 | Good | Good | Good | Good | 16147 | 52.9 |
November 1995 | Good | Good | Good | Good | 18560 | 62.3 |
February 1994 | Good | Very Good | Very Good | Very Good | 18342 | 63.7 |
March 1992 | Good | Very Good | Very Good | Very Good | 18342 | 64.7 |
May 1990 | Fair | Satisfactory | Satisfactory | Satisfactory | 17540 | 65.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 338 | 299 | 30 | 9 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,747 | 1,660 | 87 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,523 | 1,447 | 76 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 204 | 184 | 20 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 27 | 27 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 27 | 27 | 0 | 0 | 0 |