Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 58,HARRISVILLE over OVER SWAMP RUN
Structure number:000000000025682
Old structure number:430058080023880 (from 1992 edition)
Location:PINE TOWNSHIP
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:33.1 ft. [10.1 m]
Total length:35.1 ft. [10.7 m]
Roadway width between curbs:33.1 ft. [10.1 m]
Deck width edge-to-edge:37.1 ft. [11.3 m]
Owner:State Highway Agency [01]
Year built:1955
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,973 [as of 2016]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:72.8 tons [66.2 metric tons]
Inventory rating:43.9 tons [39.9 metric tons]
Sufficiency rating:84.7

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201684.7FairFairFairFair-3973
June 201484.7FairFairFairFair-4019
June 201284.6FairFairFairFair-4205
June 201083.6FairFairFairFair-4250
June 200881.5PoorPoorFairFairSD4250
June 200683.2FairFairFairFair-5387
June 200483.2FairFairFairFair-5260
June 200285.3FairSatisfactoryFairFair-5116
April 200085.3FairSatisfactoryFairFair-5026
March 199885.6FairSatisfactoryFairFair-4356
March 199685.5FairSatisfactoryFairFair-4105
April 199485.5FairGoodFairSatisfactory-4329
April 199285.5FairGoodFairSatisfactory-4252
March 199085.5FairGoodFairSatisfactory-4161

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.2722390330
Deck
Reinforced Concrete Decksq. ft.1,2781,06121700
Wearing Surfacessq. ft.1,1901,190000
Substructure
Reinforced Concrete Abutmentlinear ft.122120110
Bearings
Movable Bearingeach88000
Steel Protective Coatingsq. ft.10,75310,753000
Fixed Bearingeach88000
Steel Protective Coatingsq. ft.10,75310,753000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7070000
Steel Protective Coatingsq. ft.10,75310,753000