Share:

SR 4021,BEATTY SCH over OVER FREELAND RUN

Map

Coordinates:
+41.42477, -80.28802
41°25'29" N, 80°17'17" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 4021,BEATTY SCH over OVER FREELAND RUN
Structure number:000000000026062
Old structure number:434021007002370 (from 1992 edition)
Location:SALEM TOWNSHIP
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:24.0 ft. [7.3 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:23.0 ft. [7.0 m]
Deck width edge-to-edge:24.6 ft. [7.5 m]
Owner:State Highway Agency [01]
Year built:1915
Year reconstructed:1992
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 22.5 / HS 25 [9]
Main span material:Concrete [1]
Main span design:Channel beam [22]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:234 [as of 2015]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:88.3

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201688.3FairGoodGoodSatisfactory-234
November 201489.3FairGoodGoodSatisfactory-166
November 201289.3FairGoodGoodSatisfactory-174
November 201090.3GoodGoodGoodGood-178
November 200890.3GoodGoodGoodGood-178
November 200683.7GoodGoodGoodGood-258
November 200484.7GoodGoodGoodGood-255
November 200290.4GoodGoodGoodGood-148
November 200090.4GoodGoodGoodGood-148
December 199890.4GoodGoodGoodGood-148
December 199685.6GoodGoodGoodGood-399
December 199485.1GoodGoodGoodGood-385
December 199283.1GoodGoodVery GoodGood-380
December 199057.2FairSatisfactoryFairSatisfactoryFO369

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.184184000
Deck
Reinforced Concrete Decksq. ft.578578000
Wearing Surfacessq. ft.578578000
Concrete Protective Coatingsq. ft.578578000
Substructure
Masonry Abutmentlinear ft.7878000
Bearings
Elastomeric Bearingeach1616000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7979000
Steel Protective Coatingsq. ft.10,75310,753000