Share:

BRIDGE 506,T-825 over OVER SCHOFIELDS RUN

Map

Coordinates:
+41.44025, -80.13294
41°26'25" N, 80°07'59" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:BRIDGE 506,T-825 over OVER SCHOFIELDS RUN
Structure number:000000000026088
Old structure number:437202082505060 (from 1992 edition)
Location:SMOLA RD.,DEER CREEK TWP
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:20.0 ft. [6.1 m]
Total length:22.0 ft. [6.7 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Skew angle:20°
Owner:County Highway Agency [02]
Year built:1979
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:30 [as of 2015]
Truck traffic:4% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:61.8 tons [56.2 metric tons]
Inventory rating:37.0 tons [33.6 metric tons]
Sufficiency rating:98.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
April 201598.0Good7 out of 10-30
April 201398.0Good7 out of 10-32
April 201198.0Good7 out of 10-27
April 200998.0Good7 out of 10-38
May 200798.0Good8 out of 10-61
May 200598.0Good8 out of 10-41
May 200398.0Good8 out of 10-65
June 200198.0Good9 out of 10-63
June 199998.0Good9 out of 10-73
June 199798.0Good9 out of 10-88
May 199598.0Good9 out of 10-61
April 199396.5Good9 out of 10-159
April 199196.5Good9 out of 10-159