Share:

BRIDGE 208,T-570 over OVER BLUFF RUN

Map

Coordinates:
+41.46926, -80.34170
41°28'09" N, 80°20'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BRIDGE 208,T-570 over OVER BLUFF RUN
Structure number:000000000026278
Old structure number:437227057002080 (from 1992 edition)
Location:GROOVER RD,SUGAR GROVE
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:20.0 ft. [6.1 m]
Total length:22.0 ft. [6.7 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Owner:County Highway Agency [02]
Year built:1974
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2015

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:236 [as of 2015]
Truck traffic:4% of total traffic
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:13.0 tons [11.8 metric tons]
Inventory rating:7.0 tons [6.4 metric tons]
Sufficiency rating:42.4

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
April 201542.4Fair5 out of 10FO236
April 201342.0Fair5 out of 10FO298
April 201142.3Fair5 out of 10FO271
April 200942.2Fair5 out of 10FO346
April 200750.3Good7 out of 10FO380
May 200650.4Good7 out of 10FO296
April 200550.2Good7 out of 10FO296
May 200450.1Good7 out of 10FO354
April 200350.1Good7 out of 10FO354
May 200170.7Good7 out of 10-431
June 199970.8Good7 out of 10-365
June 199770.9Good7 out of 10-265
May 199570.8Good7 out of 10-326
April 199365.1Good7 out of 10-200
April 199165.2Good8 out of 10-99

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Culvert
Reinforced Concrete Culvertlinear ft.3434000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4444000