Share:

SR 87 over OVER WOLF RUN

Map

Coordinates:
+41.53257, -76.28314
41°31'57" N, 76°16'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 87 over OVER WOLF RUN
Structure number:000000000031974
Old structure number:560087070012760 (from 1992 edition)
Location:1 MI EAST OF COLLEY
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:25.9 ft. [7.9 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:23.6 ft. [7.2 m]
Deck width edge-to-edge:26.2 ft. [8.0 m]
Owner:State Highway Agency [01]
Year built:1934
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:550 [as of 2015]
Truck traffic:18% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Operating rating:53.9 tons [49.0 metric tons]
Inventory rating:31.9 tons [29.0 metric tons]
Sufficiency rating:63.0
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$147,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201663.0FairSatisfactoryFairFair-550
November 201462.0FairSatisfactoryFairFair-657
November 201260.8FairSatisfactoryFairFair-664
November 201067.3FairSatisfactoryFairFair-667
November 200868.4FairSatisfactoryFairFair-649
November 200672.4FairGoodFairFair-638
November 200471.3FairGoodFairFair-598
November 200276.4FairGoodFairFair-582
November 200075.4FairSatisfactoryFairFair-576
November 199875.4FairSatisfactoryFairFair-581
November 199668.8FairSatisfactoryFairFair-1950
November 199468.9FairSatisfactoryFairFair-1886
November 199269.9FairSatisfactoryFairSatisfactory-1860

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.157659020
Deck
Reinforced Concrete Decksq. ft.710703700
Wearing Surfacessq. ft.648648000
Substructure
Reinforced Concrete Abutmentlinear ft.100356500
Bearings
Fixed Bearingeach1212000
Steel Protective Coatingsq. ft.10,75310,753000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5454000