SR 3003 over OVER COLD RUN
Map
Coordinates:
+40.88724, -77.1406040°53'14" N, 77°08'26" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 3003 over OVER COLD RUN |
Structure number: | 000000000033545 |
Old structure number: | 593003001026560 (from 1992 edition) |
Location: | VILLAGE OF MILLMONT |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 32.2 ft. [9.8 m] |
Total length: | 32.2 ft. [9.8 m] |
Roadway width between curbs: | 24.3 ft. [7.4 m] |
Deck width edge-to-edge: | 25.9 ft. [7.9 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 1932 |
Year reconstructed: | 2006 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 341 [as of 2018] |
Truck traffic: | 8% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 76.9 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Good | Satisfactory | Fair | 341 | 76.9 |
May 2016 | Fair | Very Good | Satisfactory | Fair | 340 | 76.9 |
May 2014 | Fair | Very Good | Satisfactory | Fair | 318 | 76.9 |
May 2012 | Fair | Very Good | Satisfactory | Fair | 326 | 67.5 |
May 2010 | Fair | Very Good | Good | Fair | 328 | 67.0 |
May 2008 | Fair | Very Good | Good | Fair | 410 | 67.0 |
August 2006 | Fair | Very Good | Good | Fair | 399 | 79.4 |
May 2005 | Fair | Fair | Fair | Fair | 399 | 65.7 |
May 2004 | Fair | Fair | Fair | Fair | 392 | 65.7 |
May 2003 | Fair | Fair | Fair | Fair | 386 | 64.7 |
May 2002 | Fair | Fair | Fair | Fair | 379 | 64.7 |
May 2001 | Fair | Fair | Fair | Fair | 375 | 64.7 |
May 2000 | Fair | Fair | Fair | Fair | 375 | 64.7 |
May 1999 | Fair | Fair | Fair | Fair | 375 | 69.7 |
May 1998 | Fair | Fair | Fair | Fair | 543 | 68.6 |
May 1997 | Fair | Fair | Fair | Fair | 532 | 68.6 |
May 1996 | Fair | Fair | Fair | Fair | 522 | 68.6 |
May 1995 | Fair | Fair | Fair | Fair | 512 | 68.7 |
May 1994 | Fair | Fair | Fair | Fair | 504 | 68.7 |
May 1993 | Fair | Fair | Fair | Fair | 497 | 68.7 |
May 1992 | Fair | Fair | Fair | Fair | 497 | 68.7 |
May 1991 | Fair | Fair | Fair | Fair | 481 | 72.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 221 | 167 | 40 | 14 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Substructure |
Masonry Abutment | linear ft. | 93 | 63 | 10 | 20 | 0 |
Deck |
Timber Deck | sq. ft. | 794 | 0 | 794 | 0 | 0 |
Wearing Surfaces | sq. ft. | 794 | 794 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 7 | 4 | 3 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Fixed Bearing | each | 7 | 7 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 76 | 61 | 15 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |