Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 1002 over DELAWARE RIVER
Structure number:000000000035588
Old structure number:631002023007390 (from 1992 edition)
Location:DAMASCUS TP SKINNERS FLLS
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:232.0 ft. [70.7 m]
Total length:466.9 ft. [142.3 m]
Roadway width between curbs:13.1 ft. [4.0 m]
Deck width edge-to-edge:16.7 ft. [5.1 m]
Vertical clearance above deck:15.7 ft. [4.8 m]
Owner:State Highway Agency [01]
Year built:1901
Year reconstructed:1980
Historic significance:Bridge is on the National Register of Historic Places [1]
Design load:M 18 / H 20 [4]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: November 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:323 [as of 2017]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Serious [3 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:15.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$3,599,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2018PoorFairPoorSerious32315.8
May 2017PoorFairPoorSerious32315.8
November 2015PoorFairPoorSerious29016.1
November 2013PoorFairPoorSerious28916.1
February 2013PoorFairSeriousSerious28716.1
February 2011PoorFairSeriousSerious40415.0
October 2009PoorFairSeriousSerious39915.0
March 2009PoorFairSeriousSerious39915.0
March 2008PoorFairSeriousSatisfactory38615.2
October 2006PoorFairSeriousSatisfactory39615.1
February 2006PoorFairSeriousSatisfactory38315.2
February 2005PoorFairSeriousSatisfactory37215.3
September 2003PoorFairSeriousSatisfactory36515.4
October 2002PoorFairSeriousSatisfactory36515.4
October 2001PoorFairPoorSatisfactory86010.4
November 2000PoorFairPoorSatisfactory85010.5
November 1999PoorFairPoorSatisfactory82910.7
November 1998PoorFairPoorSatisfactory82910.7
November 1997FairFairFairSatisfactory32221.2
November 1996FairFairFairSatisfactory31421.2
November 1995PoorFairPoorSatisfactory30316.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Stringerlinear ft.5,104005,1040
Steel Protective Coatingsq. ft.21,50621,506000
Steel Trusslinear ft.9280832960
Steel Protective Coatingsq. ft.21,50621,506000
Steel Floor Beamlinear ft.382038200
Steel Protective Coatingsq. ft.21,50621,506000
Substructure
Masonry Pier Walllinear ft.3103100
Masonry Abutmentlinear ft.166016600
Joints
Assembly without Seal Jointlinear ft.3603600
Deck
Timber Decksq. ft.6,84406,84400
Bearings
Movable Bearingeach40004
Steel Protective Coatingsq. ft.21,50621,506000
Fixed Bearingeach40004
Steel Protective Coatingsq. ft.21,50621,506000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.934934000
Steel Protective Coatingsq. ft.21,50621,506000