Share:

COTTMAN AVENUE over ROOSEVELT BLVD.

Map 

Coordinates:
+40.04444, -75.05428
40°02'40" N, 75°03'15" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:COTTMAN AVENUE over ROOSEVELT BLVD.
Structure number:000000000038436
Old structure number:670073005000000 (from 1992 edition)
Location:@ ROOSEVELT BLVD. 3482B03
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:48.9 ft. [14.9 m]
Total length:102.0 ft. [31.1 m]
Roadway width between curbs:72.5 ft. [22.1 m]
Deck width edge-to-edge:90.6 ft. [27.6 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Skew angle:13°
Owner:State Highway Agency [01]
Year built:1967
Year reconstructed:2012
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Prestressed concrete [5]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2016 

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:22,689 [as of 2016]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:71.8 tons [65.3 metric tons]
Inventory rating:42.9 tons [39.0 metric tons]
Sufficiency rating:55.3
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,096,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201655.3PoorSatisfactoryFairPoor-22689
March 201449.9PoorSatisfactoryFairPoor-20624
March 201256.1PoorSatisfactoryFairPoor-10802
March 201054.4PoorSatisfactoryFairPoorSD13476
March 200853.4PoorSatisfactorySatisfactoryPoorSD13476
March 200647.0PoorSatisfactorySatisfactoryPoorSD27071
February 200448.0PoorSatisfactorySatisfactoryPoorSD26154
March 200250.0PoorSatisfactorySatisfactoryPoorSD34931
July 199950.0PoorSatisfactorySatisfactoryPoorSD42302
August 199767.0FairSatisfactorySatisfactoryFairFO41020
September 199566.0FairFairSatisfactoryFairFO39198
January 199468.0FairGoodSatisfactoryFairFO38280
January 199278.9FairVery GoodSatisfactorySatisfactoryFO35890