Share:

INTERSTATE 95 S.B. over FRANKFD AV,FRNKFRD EL.

Map

Coordinates:
+39.96425, -75.13864
39°57'51" N, 75°08'19" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:INTERSTATE 95 S.B. over FRANKFD AV,FRNKFRD EL.
Structure number:000000000038590
Old structure number:670095022500000 (from 1992 edition)
Location:N.BEN FRANKLIN BR3590H06
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:143.1 ft. [43.6 m]
Total length:1589.0 ft. [484.3 m]
Roadway width between curbs:66.6 ft. [20.3 m]
Deck width edge-to-edge:70.5 ft. [21.5 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1977
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:13
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:92,736 [as of 2017]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:79.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactorySatisfactoryFair9273679.0
October 2015FairSatisfactorySatisfactoryFair10688778.2
October 2013FairSatisfactorySatisfactoryFair8433379.5
November 2011FairSatisfactorySatisfactoryFair8213879.6
December 2009FairSatisfactorySatisfactoryFair7778082.8
December 2007FairSatisfactoryGoodSatisfactory9497586.3
December 2005FairSatisfactoryGoodSatisfactory8683186.9
November 2003FairSatisfactoryGoodSatisfactory8413987.1
November 2001FairSatisfactoryGoodSatisfactory8456790.1
March 1999FairSatisfactorySatisfactoryFair8364876.0
December 1996FairSatisfactoryGoodSatisfactory7667588.4
January 1995FairSatisfactoryGoodSatisfactory7262690.2
March 1993FairSatisfactoryGoodSatisfactory7758589.8
March 1991FairSatisfactoryFairSatisfactory7351778.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.15,30112,2433,05530
Steel Protective Coatingsq. ft.150,544150,544000
Deck
Reinforced Concrete Decksq. ft.116,1110116,11100
Superstructure
Steel Floor Beamlinear ft.137132500
Steel Protective Coatingsq. ft.21,50621,506000
Substructure
Reinforced Concrete Columneach3724850
Reinforced Concrete Abutmentlinear ft.1731553150
Reinforced Concrete Pier Caplinear ft.78470646320
Joints
Strip Seal Jointlinear ft.51615735900
Bearings
Movable Bearingeach137528500
Steel Protective Coatingsq. ft.139,791139,791000
Fixed Bearingeach5959000
Steel Protective Coatingsq. ft.64,51964,519000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.3,2003,191630