Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:DELAWARE EXPWAY. over SERGEANT & HUNTINGDON ST
Structure number:000000000038595
Old structure number:670095023400000 (from 1992 edition)
Location:NR.ARAMINGO AVE. 3591B05
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:63.0 ft. [19.2 m]
Total length:1365.2 ft. [416.1 m]
Roadway width between curbs:113.9 ft. [34.7 m]
Deck width edge-to-edge:121.4 ft. [37.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1965
Year reconstructed:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:21
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: January 2016

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:171,508 [as of 2016]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:51.9
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$34,020,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2016PoorFairPoorPoor17150851.9
January 2014PoorFairPoorPoor15798451.8
January 2012PoorFairPoorPoor7657551.9
February 2010PoorFairPoorPoor7493851.9
February 2008PoorFairPoorPoor18995043.8
February 2006PoorFairPoorPoor17922043.8
February 2004PoorFairPoorPoor16827848.5
February 2002PoorFairFairPoor16365948.5
March 1999PoorFairSatisfactoryPoor17879448.5
January 1997PoorSatisfactorySatisfactoryPoor16388950.5
January 1995PoorSatisfactorySatisfactoryPoor15523450.5
February 1993PoorSatisfactorySatisfactoryPoor16104350.5
March 1991PoorSatisfactorySatisfactoryPoor15260150.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.23,91923,1613783800
Deck
Reinforced Concrete Decksq. ft.165,585157,3068,27900
Wearing Surfacessq. ft.153,8460153,84600
Substructure
Reinforced Concrete Columneach84611670
Reinforced Concrete Pier Caplinear ft.2,5202,1841282080
Joints
Assembly without Seal Jointlinear ft.968968000
Other Jointlinear ft.1,1542447890121
Bearings
Elastomeric Bearingeach504504000
Movable Bearingeach252024309
Steel Protective Coatingsq. ft.150,544150,544000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5,4605,460000