Share:

DELAWARE EXPWAY. over CAMBRIA;ANN STREETS

Map

Coordinates:
+39.97909, -75.10880
39°58'45" N, 75°06'32" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:DELAWARE EXPWAY. over CAMBRIA;ANN STREETS
Structure number:000000000038599
Old structure number:670095024000000 (from 1992 edition)
Location:N.OF LEHIGH AVE. 3591C04
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:101.1 ft. [30.8 m]
Total length:905.9 ft. [276.1 m]
Roadway width between curbs:116.8 ft. [35.6 m]
Deck width edge-to-edge:121.4 ft. [37.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1966
Year reconstructed:1984
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:9
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: January 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:171,508 [as of 2016]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:73.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$20,183,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2016FairFairFairSatisfactory17150873.0
January 2014FairFairFairSatisfactory15798473.0
January 2012FairFairFairSatisfactory7657573.0
October 2009PoorFairPoorSatisfactory7493857.0
March 2008PoorFairFairPoor18995057.0
September 2005PoorFairFairPoor17366256.0
October 2003PoorFairFairPoor16827856.0
December 2001PoorFairFairPoor16365956.0
February 1999FairFairFairFair17879472.0
December 1996FairSatisfactoryFairFair16388973.0
January 1995FairSatisfactoryFairFair15523473.0
January 1993FairSatisfactoryFairFair16104373.0
March 1991FairSatisfactoryFairFair15260173.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.14,82414,08474000
Steel Protective Coatingsq. ft.96,77896,778000
Steel Stringerlinear ft.3,6123,41220000
Steel Protective Coatingsq. ft.96,77896,778000
Deck
Reinforced Concrete Decksq. ft.109,656107,2302,42600
Wearing Surfacessq. ft.101,88099,6262,25400
Superstructure
Steel Floor Beamlinear ft.1,2791,07920000
Steel Protective Coatingsq. ft.118,285118,285000
Steel Pin or Pin & Hangar Assemblyeach40400
Steel Protective Coatingsq. ft.10,75310,753000
Substructure
Reinforced Concrete Columneach2220110
Reinforced Concrete Abutmentlinear ft.1261042020
Joints
Assembly without Seal Jointlinear ft.246246000
Other Jointlinear ft.242240200
Bearings
Movable Bearingeach3026400
Steel Protective Coatingsq. ft.53,76653,766000
Fixed Bearingeach1414000
Steel Protective Coatingsq. ft.53,76653,766000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.3,6163,616000