Share:

ERIE AVENUE AT 11T over CONRAIL'RICHMOND BRANCH

Map

Coordinates:
+40.00852, -75.14544
40°00'31" N, 75°08'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ERIE AVENUE AT 11T over CONRAIL'RICHMOND BRANCH
Structure number:000000000038733
Old structure number:671004003000000 (from 1992 edition)
Location:BW10/1TH ST 3480G09
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:65.0 ft. [19.8 m]
Total length:65.0 ft. [19.8 m]
Roadway width between curbs:64.3 ft. [19.6 m]
Deck width edge-to-edge:88.3 ft. [26.9 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:26°
Owner:State Highway Agency [01]
Year built:1995
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Main span material:Prestressed concrete [5]
Main span design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,733 [as of 2016]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:92.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016FairGoodGoodSatisfactory973392.6
June 2014FairGoodGoodSatisfactory982094.6
June 2012FairGoodGoodSatisfactory749194.9
June 2010FairGoodGoodSatisfactory751194.9
July 2008FairGoodGoodSatisfactory1237594.2
July 2006FairGoodGoodSatisfactory1212094.2
July 2004FairGoodGoodSatisfactory1200094.2
May 2002FairGoodGoodSatisfactory912298.7
May 2000FairSatisfactoryVery GoodSatisfactory894398.7
January 1998GoodVery GoodExcellentGood1627097.7
April 1996GoodExcellentExcellentGood786594.8
January 1996GoodExcellentGoodGood1345690.9
April 1994PoorSeriousPoorPoor1345652.3
April 1992PoorSeriousPoorFair1345652.3
August 1990PoorSeriousPoorSatisfactory1345652.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.84258325900
Deck
Reinforced Concrete Decksq. ft.5,88505,88500
Substructure
Reinforced Concrete Abutmentlinear ft.2682343400
Bearings
Elastomeric Bearingeach3333000
Bridge Rail