Share:

ERIE AVENUE over CONRAIL(TRACKS REMOVED)

Map

Coordinates:
+40.00694, -75.13472
40°00'25" N, 75°08'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ERIE AVENUE over CONRAIL(TRACKS REMOVED)
Structure number:000000000038734
Old structure number:671004004004610 (from 1992 edition)
Location:BETWEEN 3RD & 5TH 3480J09
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:102.0 ft. [31.1 m]
Total length:116.1 ft. [35.4 m]
Roadway width between curbs:48.6 ft. [14.8 m]
Deck width edge-to-edge:69.9 ft. [21.3 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Owner:State Highway Agency [01]
Year built:1896
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Girder and floorbeam system [03]
Deck type:Closed Grating [4]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:14,635 [as of 2016]
Truck traffic:7% of total traffic
Deck condition:Serious [3 out of 9]
Superstructure condition:Serious [3 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:12.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$2,914,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2016PoorSeriousSeriousPoor1463512.0
May 2014PoorSeriousSeriousPoor1522812.0
May 2012PoorSeriousSeriousPoor1140712.0
May 2010PoorSeriousSeriousPoor1143731.9
May 2008PoorSeriousSeriousPoor1959433.0
May 2006PoorSeriousPoorPoor1919040.8
March 2004PoorSeriousPoorPoor1900040.5
March 2002PoorSeriousPoorPoor691448.5
February 2000PoorSeriousPoorPoor691429.4
January 1998FairFairFairSatisfactory691449.6
January 1996PoorPoorFairPoor640743.2
August 1994FairFairFairFair625779.3
August 1992FairFairFairFair614679.3
August 1990PoorPoorFairFair586677.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.20401206024
Steel Protective Coatingsq. ft.10,75310,753000
Steel Stringerlinear ft.1,63201,5622050
Steel Protective Coatingsq. ft.10,75310,753000
Steel Floor Beamlinear ft.7093670360
Steel Protective Coatingsq. ft.10,75310,753000
Substructure
Masonry Pier Walllinear ft.140013046
Masonry Abutmentlinear ft.1400012614
Deck
Concrete Filled Grid Decksq. ft.8,1080008,108
Steel Protective Coatingsq. ft.10,75310,753000
Joints
Assembly without Seal Jointlinear ft.140132503
Bearings
Movable Bearingeach20002
Steel Protective Coatingsq. ft.10,75310,753000
Fixed Bearingeach20002
Steel Protective Coatingsq. ft.10,75310,753000