Share:

ERIE AVENUE over CONRAIL(TRACK REMOVED)

Map

Coordinates:
+40.00669, -75.13262
40°00'24" N, 75°07'57" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ERIE AVENUE over CONRAIL(TRACK REMOVED)
Structure number:000000000038735
Old structure number:671004004006020 (from 1992 edition)
Location:BTWN.3RD & 5TH ST.3480J09
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:42.0 ft. [12.8 m]
Total length:86.9 ft. [26.5 m]
Roadway width between curbs:48.6 ft. [14.8 m]
Deck width edge-to-edge:81.0 ft. [24.7 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1917
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:14,635 [as of 2016]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:47.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,014,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2016PoorFairPoorSatisfactory1463547.5
May 2014PoorFairPoorSatisfactory1522849.3
May 2012PoorFairPoorSatisfactory1140749.4
May 2010PoorFairPoorSatisfactory1143747.2
May 2008PoorFairPoorSatisfactory1959446.2
April 2006PoorFairPoorSatisfactory1919046.4
March 2004PoorFairPoorSatisfactory1900046.2
April 2002PoorFairPoorSatisfactory1887748.1
April 1999PoorFairPoorSatisfactory1382850.3
January 1997PoorSatisfactoryPoorSatisfactory680754.5
January 1996PoorPoorPoorSatisfactory1143635.5
August 1994PoorFairPoorSatisfactory1143617.7
September 1992PoorFairPoorSatisfactory1143617.7
August 1990PoorFairPoorSatisfactory1143617.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,193143505237308
Deck
Reinforced Concrete Decksq. ft.6,9834,0503492,5840
Wearing Surfacessq. ft.5,4795,20527400
Substructure
Reinforced Concrete Pier Walllinear ft.14010920110
Reinforced Concrete Abutmentlinear ft.1407255130
Masonry Abutmentlinear ft.1404010000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.172172000