Share:

ACADEMY ROAD over WALTONS RUN CREEK

Map

Coordinates:
+40.08919, -74.98498
40°05'21" N, 74°59'06" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ACADEMY ROAD over WALTONS RUN CREEK
Structure number:000000000038775
Old structure number:671013009000000 (from 1992 edition)
Location:NEAR COMLY ROAD 3373C06
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:28.9 ft. [8.8 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:66.6 ft. [20.3 m]
Deck width edge-to-edge:88.6 ft. [27.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1960
Year reconstructed:2002
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:12,165 [as of 2015]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present desirable criteria [8]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:79.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2016FairSatisfactorySatisfactoryFair1216579.3
February 2014FairSatisfactorySatisfactoryFair1663476.8
February 2012FairSatisfactorySatisfactoryFair833781.3
February 2010FairSatisfactorySatisfactoryFair835981.4
February 2008FairSatisfactorySatisfactoryFair781381.7
March 2006FairSatisfactorySatisfactoryFair1496680.9
February 2004FairSatisfactorySatisfactoryFair2556375.2
February 2002FairSatisfactorySatisfactoryFair2464473.7
September 1999FairSatisfactorySatisfactoryFair2370873.2
September 1997FairSatisfactorySatisfactoryFair2139875.5
October 1995FairGoodGoodFair2044876.4
January 1994FairGoodSatisfactoryFair1996976.7
January 1992FairGoodSatisfactoryFair1961677.9
March 1990FairGoodGoodSatisfactory1919389.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.4364231030
Deck
Reinforced Concrete Decksq. ft.2,6572,49815900
Wearing Surfacessq. ft.1,9971,997000
Substructure
Reinforced Concrete Abutmentlinear ft.177172500
Bearings
Enclosed/Concealed Bearingeach3232000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.6161000