Share:

GIRARD AVENUE over CSX;BELMONT BRANCH

Map

Coordinates:
+39.97501, -75.18704
39°58'30" N, 75°11'13" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:GIRARD AVENUE over CSX;BELMONT BRANCH
Structure number:000000000038834
Old structure number:672008000207680 (from 1992 edition)
Location:BTWN.33RD;31TH STS.3590A4
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:68.9 ft. [21.0 m]
Total length:121.1 ft. [36.9 m]
Roadway width between curbs:52.2 ft. [15.9 m]
Deck width edge-to-edge:52.2 ft. [15.9 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:31°
Owner:State Highway Agency [01]
Year built:1925
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Main span material:Concrete continuous [2]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,035 [as of 2015]
Truck traffic:8% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:78.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$549,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016FairFairFairFair1003578.5
June 2014FairFairFairFair1015580.5
June 2012FairFairFairFair1021180.5
June 2010FairFairFairFair1016480.5
July 2008FairFairFairFair1014280.5
August 2006FairFairFairFair1077980.3
August 2004FairFairFairFair1052583.5
July 2002FairFairFairFair1014684.7
October 1999FairFairFairFair994781.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,6971,3162521290
Deck
Reinforced Concrete Decksq. ft.10,1869,67750900
Wearing Surfacessq. ft.6,6176,28633100
Superstructure
Steel Floor Beamlinear ft.387038700
Steel Protective Coatingsq. ft.32,25932,259000
Substructure
Reinforced Concrete Columneach2013430
Reinforced Concrete Pier Walllinear ft.21293106130
Masonry Abutmentlinear ft.339146103900
Reinforced Concrete Pier Caplinear ft.2121981400
Bearings
Enclosed/Concealed Bearingeach8484000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.25411214200