Share:

SPRUCE & DOCK STR. over I-95; RAMP NX; RAMP XN

Map

Coordinates:
+39.94423, -75.14274
39°56'39" N, 75°08'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SPRUCE & DOCK STR. over I-95; RAMP NX; RAMP XN
Structure number:000000000038564
Old structure number:672150001000000 (from 1992 edition)
Location:PENN'S LANDING TUN.3590H9
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:71.9 ft. [21.9 m]
Total length:212.0 ft. [64.6 m]
Roadway width between curbs:71.9 ft. [21.9 m]
Deck width edge-to-edge:701.8 ft. [213.9 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1976
Year reconstructed:1990
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Other [9]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,637 [as of 2016]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:94.8

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016FairSatisfactorySatisfactorySatisfactory363794.8
June 2014FairSatisfactorySatisfactorySatisfactory367096.7
June 2012FairSatisfactorySatisfactorySatisfactory448896.2
June 2010FairSatisfactorySatisfactorySatisfactory282697.3
June 2008FairSatisfactorySatisfactorySatisfactory282097.3
May 2006FairSatisfactorySatisfactorySatisfactory278094.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.40,12839,71141430
Deck
Reinforced Concrete Decksq. ft.147,229139,8687,36100
Wearing Surfacessq. ft.13,42412,75367100
Substructure
Reinforced Concrete Pier Walllinear ft.2,3702,29265130
Reinforced Concrete Abutmentlinear ft.1,5801,5324530
Bearings
Elastomeric Bearingeach1,52476276200