Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WALNUT LANE over LINCOLN DR,MONOSHONE CK.
Structure number:000000000039075
Old structure number:674015002000000 (from 1992 edition)
Location:FAIRMOUNT PARK E. 3479K05
Purpose:Carries highway and pedestrian walkway over highway and waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:158.1 ft. [48.2 m]
Total length:309.1 ft. [94.2 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:63.7 ft. [19.4 m]
Vertical clearance below bridge:42.7 ft. [13.0 m]
Owner:State Highway Agency [01]
Year built:1949
Year reconstructed:1990
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:8,137 [as of 2016]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Sufficiency rating:95.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2016GoodGoodGoodGood813795.6
February 2014GoodGoodGoodGood821081.3
February 2012GoodGoodGoodGood684281.6
February 2010GoodGoodGoodGood786281.3
February 2008GoodGoodGoodGood784581.3
February 2006GoodGoodGoodGood798882.5
March 2004GoodGoodGoodGood804379.3
February 2002GoodGoodVery GoodGood801579.3
September 1999GoodGoodVery GoodGood688379.8
October 1997GoodVery GoodVery GoodGood753879.6
October 1995FairGoodGoodSatisfactory753879.5
February 1994FairGoodVery GoodSatisfactory736279.6
February 1992FairGoodExcellentSatisfactory723279.6
August 1990GoodVery GoodVery GoodVery Good695479.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2,3962,392400
Deck
Reinforced Concrete Decksq. ft.19,778019,77800
Substructure
Reinforced Concrete Columneach86200
Reinforced Concrete Pier Walllinear ft.120120000
Reinforced Concrete Abutmentlinear ft.138133500
Reinforced Concrete Pier Caplinear ft.1201101000
Joints
Strip Seal Jointlinear ft.128646400
Bearings
Pot Bearingeach4804800
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.620620000