Share:

WINGOHOCKING STR. over FRANKFORD CREEK

Map

Coordinates:
+40.01478, -75.09438
40°00'53" N, 75°05'40" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:WINGOHOCKING STR. over FRANKFORD CREEK
Structure number:000000000039216
Old structure number:677301012002070 (from 1992 edition)
Location:E.OF CASTOR AVE. 29F01
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:62.0 ft. [18.9 m]
Total length:69.9 ft. [21.3 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:62.0 ft. [18.9 m]
Skew angle:15°
Owner:City or Municipal Highway Agency [04]
Year built:1951
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Frame [07]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,100 [as of 1980]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:98.8 tons [89.8 metric tons]
Inventory rating:46.9 tons [42.6 metric tons]
Sufficiency rating:96.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$786,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201696.7FairSatisfactorySatisfactorySatisfactory-7100
October 201496.7FairSatisfactorySatisfactorySatisfactory-7100
October 201296.7FairSatisfactorySatisfactorySatisfactory-7100
October 201096.7FairSatisfactorySatisfactorySatisfactory-7100
October 200896.7FairSatisfactorySatisfactorySatisfactory-7100
January 200796.7FairSatisfactorySatisfactorySatisfactory-7100
October 200696.7FairSatisfactorySatisfactorySatisfactory-7100
October 200496.3FairSatisfactorySatisfactorySatisfactory-7100
October 200296.3FairSatisfactorySatisfactorySatisfactory-7100
October 200096.3FairSatisfactorySatisfactorySatisfactory-7100
October 199896.3FairSatisfactorySatisfactorySatisfactory-7100
October 199680.1FairSatisfactorySatisfactorySatisfactoryFO7100
October 199480.3FairSatisfactorySatisfactorySatisfactoryFO7100
October 199280.3FairSatisfactorySatisfactorySatisfactoryFO7100
October 199073.3PoorPoorSatisfactorySatisfactorySD7100