Share:

MARKET STREET WEST over I-95,RAMPS,COLUMBUS BLVD

Map

Coordinates:
+39.94989, -75.14178
39°56'60" N, 75°08'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MARKET STREET WEST over I-95,RAMPS,COLUMBUS BLVD
Structure number:000000000039275
Old structure number:677360990065560 (from 1992 edition)
Location:.3MI.S.BEN FRKN.BR.3590H9
Purpose:Carries highway and pedestrian walkway over highway and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:126.0 ft. [38.4 m]
Total length:747.1 ft. [227.7 m]
Roadway width between curbs:25.6 ft. [7.8 m]
Deck width edge-to-edge:53.2 ft. [16.2 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1976
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:6
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,665 [as of 2016]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:65.4
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,040,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2016FairSatisfactorySatisfactoryFair266565.4
March 2014FairSatisfactorySatisfactorySatisfactory122178.8
March 2012FairSatisfactorySatisfactorySatisfactory520078.0
April 2010FairSatisfactorySatisfactorySatisfactory520078.0
April 2008FairSatisfactorySatisfactorySatisfactory520078.0
April 2006FairSatisfactoryGoodSatisfactory520075.0
April 2004FairSatisfactoryGoodSatisfactory520075.0
March 2002FairGoodGoodSatisfactory520075.0
February 2000FairGoodGoodSatisfactory520075.0
January 1998GoodGoodGoodGood520066.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.5,1872,6932,437570
Steel Protective Coatingsq. ft.86,02586,025000
Deck
Reinforced Concrete Decksq. ft.39,273039,27300
Substructure
Reinforced Concrete Columneach65010
Reinforced Concrete Pier Walllinear ft.2101574760
Reinforced Concrete Abutmentlinear ft.9586720
Reinforced Concrete Pier Caplinear ft.3062574090
Joints
Compression Jointlinear ft.43201080324
Bearings
Movable Bearingeach5674900
Steel Protective Coatingsq. ft.86,02586,025000
Fixed Bearingeach4983902
Steel Protective Coatingsq. ft.75,27275,272000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,4041,404000