Share:

RAMP D S.B. OFF over TERMINAL AVENUE

Map

Coordinates:
+39.89889, -75.17333
39°53'56" N, 75°10'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP D S.B. OFF over TERMINAL AVENUE
Structure number:000000000038718
Old structure number:678001050000000 (from 1992 edition)
Location:BROAD ST.INTERCH. 3700C07
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:94.2 ft. [28.7 m]
Total length:288.1 ft. [87.8 m]
Roadway width between curbs:22.6 ft. [6.9 m]
Deck width edge-to-edge:28.2 ft. [8.6 m]
Vertical clearance below bridge:9.8 ft. [3.0 m]
Owner:State Highway Agency [01]
Year built:1969
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,717 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:74.2
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$537,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairSatisfactorySatisfactoryFair571774.2
May 2015FairSatisfactorySatisfactoryFair628075.9
June 2013FairSatisfactorySatisfactoryFair628075.9
June 2011FairSatisfactorySatisfactoryFair529976.4
June 2009FairSatisfactorySatisfactoryFair4779.0
June 2007FairSatisfactorySatisfactoryFair4780.0
June 2005FairSatisfactorySatisfactoryFair4780.0
June 2003FairSatisfactorySatisfactoryFair4580.0
July 2001FairGoodSatisfactorySatisfactory4395.0
March 1999FairSatisfactorySatisfactorySatisfactory4291.0
January 1997FairSatisfactoryGoodSatisfactory4193.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,31065265530
Steel Protective Coatingsq. ft.32,25932,259000
Deck
Reinforced Concrete Decksq. ft.9,4359,12331200
Wearing Surfacessq. ft.8,2798,00527400
Superstructure
Steel Floor Beamlinear ft.2626000
Steel Protective Coatingsq. ft.10,75310,753000
Substructure
Reinforced Concrete Pier Walllinear ft.1818000
Reinforced Concrete Abutmentlinear ft.4442200
Reinforced Concrete Pier Caplinear ft.6052440
Joints
Strip Seal Jointlinear ft.5656000
Assembly without Seal Jointlinear ft.3729800
Bearings
Movable Bearingeach1404010
Steel Protective Coatingsq. ft.32,25932,259000
Fixed Bearingeach50500
Steel Protective Coatingsq. ft.10,75310,753000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.578574400