40°00'09" N, 75°11'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP D OF US-1 over RAMP CLW TO SCHUYLKILL
Structure number:000000000039326
Old structure number:678004026009220 (from 1992 edition)
Location:RT76;US1 INTERCHA;3479J10
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:108.9 ft. [33.2 m]
Total length:120.1 ft. [36.6 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:73°
Owner:State Highway Agency [01]
Year built:1970
Year reconstructed:2012
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:25,697 [as of 2016]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:79.4
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$197,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016FairSatisfactorySatisfactorySatisfactory2569779.4
June 2014FairSatisfactorySatisfactorySatisfactory2926679.6
June 2012PoorSatisfactorySatisfactoryPoor2663852.0
June 2010PoorSatisfactorySatisfactoryPoor1210262.7
June 2008PoorSatisfactorySatisfactoryPoor3396556.0
June 2006FairSatisfactorySatisfactoryFair3326570.0
June 2004FairSatisfactorySatisfactoryFair3248170.0
April 2002FairSatisfactoryGoodFair3131370.0
October 1999FairSatisfactoryGoodFair3060570.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.65354011300
Steel Protective Coatingsq. ft.10,75310,753000
Deck
Reinforced Concrete Decksq. ft.5,4565,456000
Wearing Surfacessq. ft.4,96004,96000
Substructure
Reinforced Concrete Abutmentlinear ft.2892741050
Joints
Strip Seal Jointlinear ft.132132000
Other Jointlinear ft.155155000
Bearings
Movable Bearingeach60600
Steel Protective Coatingsq. ft.10,75310,753000
Fixed Bearingeach66000
Steel Protective Coatingsq. ft.10,75310,753000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2322121550