Share:

RAMP NV S.B. OFF over SPRING GARDEN STREET

Map

Coordinates:
+39.96149, -75.14035
39°57'41" N, 75°08'25" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP NV S.B. OFF over SPRING GARDEN STREET
Structure number:000000000039346
Old structure number:678009051009130 (from 1992 edition)
Location:VINE ST INTERCH. 3590H07
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:62.0 ft. [18.9 m]
Total length:128.0 ft. [39.0 m]
Roadway width between curbs:75.1 ft. [22.9 m]
Deck width edge-to-edge:80.1 ft. [24.4 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1975
Year reconstructed:1991
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:12,005 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:82.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$367,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairSatisfactoryFairFair1200582.8
April 2015FairSatisfactoryFairFair1181484.8
May 2013FairSatisfactoryFairFair1181480.6
September 2011FairSatisfactorySatisfactoryFair1473279.8
September 2009FairSatisfactorySatisfactoryFair2847575.9
September 2007FairSatisfactorySatisfactoryFair2835675.9
August 2005FairSatisfactorySatisfactoryFair2761280.6
September 2003FairGoodSatisfactoryFair2690880.8
September 2001FairGoodSatisfactoryFair2573582.1
February 1999FairGoodGoodFair2525482.2
January 1997FairGoodGoodFair2410381.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,3461,22170550
Steel Protective Coatingsq. ft.21,50621,506000
Deck
Reinforced Concrete Decksq. ft.10,68810,41627200
Wearing Surfacessq. ft.10,1769,91725900
Substructure
Reinforced Concrete Columneach54100
Reinforced Concrete Abutmentlinear ft.1838845500
Reinforced Concrete Pier Caplinear ft.8383000
Joints
Compression Jointlinear ft.8608600
Bearings
Movable Bearingeach2202200
Steel Protective Coatingsq. ft.21,50621,506000
Fixed Bearingeach1111000
Steel Protective Coatingsq. ft.10,75310,753000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.128128000
Steel Protective Coatingsq. ft.21,50621,506000
Reinforced Concrete Bridge Raillinear ft.128126200