Share:

RAMP F & J(NB. ON) over PENROSE AVE. & RAMP

Map

Coordinates:
+39.88509, -75.24183
39°53'06" N, 75°14'31" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RAMP F & J(NB. ON) over PENROSE AVE. & RAMP
Structure number:000000000039441
Old structure number:678047078000000 (from 1992 edition)
Location:N.PHILA.AIRPORT 3699B09
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:141.1 ft. [43.0 m]
Total length:629.0 ft. [191.7 m]
Roadway width between curbs:39.0 ft. [11.9 m]
Deck width edge-to-edge:43.6 ft. [13.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1984
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:19,160 [as of 2016]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:84.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2016FairGoodGoodSatisfactory1916084.0
June 2014FairGoodGoodSatisfactory1074873.6
June 2012FairGoodGoodSatisfactory750574.6
June 2010FairGoodGoodSatisfactory755674.6
June 2008FairGoodGoodSatisfactory111183.7
May 2006FairVery GoodGoodSatisfactory108885.7
April 2004FairVery GoodGoodSatisfactory106287.7
March 2002FairVery GoodGoodSatisfactory104998.8

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.4,4414,18825300
Steel Protective Coatingsq. ft.64,51964,519000
Deck
Reinforced Concrete Decksq. ft.30,98430,27271200
Superstructure
Steel Floor Beamlinear ft.120932070
Steel Protective Coatingsq. ft.21,50621,506000
Substructure
Reinforced Concrete Columneach42110
Reinforced Concrete Pier Walllinear ft.58481000
Reinforced Concrete Abutmentlinear ft.1341101950
Reinforced Concrete Pier Caplinear ft.142954610
Joints
Strip Seal Jointlinear ft.266026600
Bearings
Movable Bearingeach45143100
Steel Protective Coatingsq. ft.53,76653,766000
Fixed Bearingeach33201300
Steel Protective Coatingsq. ft.53,76653,766000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,2841,284000