Share:

PR 3 over DEMAJAGUA RIVER

Map

Coordinates:
+18.28392, -65.63899
18°17'02" N, 65°38'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR 3 over DEMAJAGUA RIVER
Structure number:001151
Location:2.5 KM NORTH OF CEIBA
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:32.5 ft. [9.9 m]
Total length:35.4 ft. [10.8 m]
Roadway width between curbs:33.8 ft. [10.3 m]
Deck width edge-to-edge:38.7 ft. [11.8 m]
Owner:State Highway Agency [01]
Year built:1918
Year reconstructed:1968
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:13,808 [as of 2006]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:59.9
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$827,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2017PoorSatisfactoryPoorSatisfactory1380859.9
January 2016PoorSatisfactoryPoorSatisfactory1380859.9
January 2015PoorSatisfactoryPoorSatisfactory1380859.9
January 2013PoorSatisfactoryPoorSatisfactory1320060.2
February 2012PoorSatisfactoryPoorSatisfactory1320061.2
April 2009PoorSatisfactoryPoorSatisfactory1320061.2
July 2007PoorSatisfactoryPoorSatisfactory1320061.2
November 2005FairSatisfactoryFairSatisfactory1760051.0
April 2003FairSatisfactoryFairSatisfactory1630051.9
July 2000PoorSatisfactoryPoorSatisfactory1630032.8
July 1998FairSatisfactoryFairSatisfactory1610052.0
June 1996FairSatisfactoryFairSatisfactory2170047.8
August 1994FairFairFairSatisfactory2170033.3
August 1992FairFairFairFair3570031.3
January 1991PoorFairPoorFair1765023.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.31820601120
Deck
Reinforced Concrete Decksq. ft.1,3671,2818600
Wearing Surfacessq. ft.1,1951,195000
Substructure
Reinforced Concrete Abutmentlinear ft.1571411600
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.7265700