Share:

PR 128 over DE LOS PLATANOS CREEK

Map

Coordinates:
+18.26000, -66.86167
18°15'36" N, 66°51'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR 128 over DE LOS PLATANOS CREEK
Structure number:002631
Location:1 KM SOUTH OF INT PR 129
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:24.6 ft. [7.5 m]
Total length:24.6 ft. [7.5 m]
Roadway width between curbs:20.3 ft. [6.2 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Owner:State Highway Agency [01]
Year built:1941
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:700 [as of 2005]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:63.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$160,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2016FairFairFairFair70063.8
November 2014FairFairFairFair70064.2
November 2012FairFairFairFair70061.2
December 2010FairFairFairFair70063.8
December 2008FairFairFairFair70063.8
March 2007FairFairFairFair70065.9
April 2005FairFairFairFair70045.5
June 2002PoorFairFairPoor70030.3
May 2000PoorFairFairPoor70030.3
July 1998FairFairSatisfactoryFair70045.5
February 1996PoorFairFairPoor60030.3
November 1993PoorFairFairPoor30033.6
March 1992PoorFairFairPoor30033.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1511020490
Deck
Reinforced Concrete Decksq. ft.5064200860
Wearing Surfacessq. ft.50635501510
Substructure
Reinforced Concrete Abutmentlinear ft.1311151600
Joints
Compression Jointlinear ft.4343000
Bridge Rail
Other Material Bridge Raillinear ft.69460716