Share:

PR 140 over DEPRESION

Map

Coordinates:
+18.33333, -66.59833
18°19'60" N, 66°35'54" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR 140 over DEPRESION
Structure number:002981
Location:6.2 KM SOUTH OF FLORIDA
Route classification:Minor Arterial (Rural) [06]
Length of largest span:24.9 ft. [7.6 m]
Total length:122.1 ft. [37.2 m]
Roadway width between curbs:18.4 ft. [5.6 m]
Deck width edge-to-edge:23.0 ft. [7.0 m]
Owner:State Highway Agency [01]
Year built:1926
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:5
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:1,100 [as of 2005]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:2.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$824,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairFairFairSatisfactory11002.0
April 2015FairFairFairSatisfactory11002.0
April 2013FairFairFairSatisfactory11002.0
March 2011FairFairFairSatisfactory110060.0
March 2009FairFairFairSatisfactory110060.0
May 2007FairFairFairSatisfactory120061.8
June 2005FairFairFairFair120021.1
October 2002FairFairFairFair120021.1
February 2001PoorPoorSeriousPoor13002.0
April 1998PoorPoorSeriousPoor15002.0
June 1996PoorPoorSeriousPoor10002.0
June 1994PoorPoorSeriousPoor10002.0
June 1992PoorSeriousSeriousPoor100023.8
December 1990PoorPoorPoorPoor111022.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.758755300
Deck
Reinforced Concrete Top Flangesq. ft.2,3252,045861940
Wearing Surfacessq. ft.2,3252,325000
Substructure
Reinforced Concrete Columneach1212000
Reinforced Concrete Abutmentlinear ft.4646000
Joints
Compression Jointlinear ft.4949000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2532431000