Share:

OFF PR 185 over CUBUY RIVER

Map

Coordinates:
+18.31667, -65.89000
18°19'00" N, 65°53'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:OFF PR 185 over CUBUY RIVER
Structure number:013501
Location:7.5 KM SOUTH OF CANOVANAS
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:29.5 ft. [9.0 m]
Total length:63.0 ft. [19.2 m]
Roadway width between curbs:18.7 ft. [5.7 m]
Deck width edge-to-edge:20.7 ft. [6.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:350 [as of 2005]
Truck traffic:2% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:None present but re-evaluation suggested [5]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:60.3
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$295,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018FairSatisfactorySatisfactorySatisfactory35060.3
May 2016FairSatisfactorySatisfactorySatisfactory35060.3
May 2014FairSatisfactorySatisfactorySatisfactory35060.3
May 2012FairSatisfactorySatisfactorySatisfactory35056.3
June 2010FairSatisfactorySatisfactorySatisfactory35064.5
April 2008FairSatisfactoryFairSatisfactory35053.7
March 2006FairGoodFairSatisfactory35017.3
May 2004FairSatisfactoryFairSatisfactory35017.3
September 2001FairSatisfactoryFairSatisfactory35017.3
November 1999FairSatisfactoryFairSatisfactory35017.3
November 1997FairSatisfactorySatisfactorySatisfactory35032.2
August 1996FairSatisfactorySatisfactorySatisfactory35036.2
December 1994FairSatisfactorySatisfactorySatisfactory20048.5
January 1993FairSatisfactorySatisfactorySatisfactory20048.5
February 1991FairFairFairFair84036.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pier Walllinear ft.2316700
Reinforced Concrete Abutmentlinear ft.4304300
Reinforced Concrete Pile Cap/Footinglinear ft.2323000
Reinforced Concrete Pier Caplinear ft.2626000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4949000
Deck
Reinforced Concrete Slabsq. ft.1,1631,163000
Wearing Surfacessq. ft.926926000