Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LOCAL ROAD over DUEY RIVER
Structure number:014171
Location:11 KM S E OF MAYAGUEZ
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:19.4 ft. [5.9 m]
Total length:38.1 ft. [11.6 m]
Roadway width between curbs:18.4 ft. [5.6 m]
Deck width edge-to-edge:20.3 ft. [6.2 m]
Owner:City or Municipal Highway Agency [04]
Year built:1949
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:475 [as of 2005]
Truck traffic:2% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:12.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$197,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018FairFairFairFair47512.0
April 2016FairFairFairFair47546.0
March 2014FairFairFairFair47512.0
March 2013FairFairFairFair47512.0
March 2011FairFairFairFair47546.0
March 2009FairFairFairFair47546.0
June 2007FairFairFairFair47550.6
September 2005FairFairFairFair47516.3
October 2003FairFairFairFair47516.3
September 2001PoorFairFairPoor4754.0
December 1999PoorFairFairPoor4754.0
September 1997PoorFairFairPoor4754.0
January 1996PoorFairPoorPoor4503.0
May 1993PoorPoorPoorPoor4002.0
October 1991PoorFairFairPoor40026.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.1188223130
Deck
Reinforced Concrete Top Flangesq. ft.829387420220
Wearing Surfacessq. ft.753753000
Substructure
Reinforced Concrete Pier Walllinear ft.2071030
Reinforced Concrete Abutmentlinear ft.39221070
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.82492670