PR 53 over CEIBA CREEK & PR 975
Map
Coordinates:
+18.27167, -65.6500018°16'18" N, 65°39'00" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | PR 53 over CEIBA CREEK & PR 975 |
Structure number: | 023081 |
Location: | 0.8 KM NW OF CEIBA |
Purpose: | Carries highway over highway and waterway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Tolls: | Yes, on toll road [2] |
Length of largest span: | 117.1 ft. [35.7 m] |
Total length: | 249.7 ft. [76.1 m] |
Roadway width between curbs: | 80.7 ft. [24.6 m] |
Deck width edge-to-edge: | 107.6 ft. [32.8 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 26° |
Owner: | State Toll Authority [31] |
Year built: | 1994 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 20,119 [as of 2007] |
Truck traffic: | 4% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 94.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Fair | Fair | Good | Good | 20119 | 94.0 |
October 2015 | Fair | Fair | Good | Good | 20119 | 94.0 |
October 2013 | Fair | Fair | Good | Good | 20119 | 94.0 |
October 2011 | Fair | Fair | Good | Good | 19600 | 94.0 |
April 2009 | Fair | Satisfactory | Good | Good | 19600 | 95.0 |
October 2007 | Fair | Satisfactory | Good | Good | 18600 | 95.0 |
November 2005 | Good | Good | Good | Good | 18600 | 95.0 |
April 2001 | Good | Good | Good | Good | 16600 | 95.0 |
June 1999 | Good | Good | Good | Good | 12900 | 91.1 |
March 1997 | Good | Good | Very Good | Very Good | 9200 | 93.0 |
January 1995 | Good | Good | Very Good | Very Good | 12000 | 93.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 3,258 | 3,232 | 26 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 43,974 | 24,070 | 18,728 | 1,176 | 0 |
Substructure |
Reinforced Concrete Column | each | 12 | 12 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 454 | 433 | 21 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 107 | 90 | 17 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 325 | 150 | 124 | 51 | 0 |
Bearings |
Elastomeric Bearing | each | 80 | 80 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 1,301 | 1,250 | 51 | 0 | 0 |