RI 114/103 CNTY RD over WARREN RIVER
Map
Coordinates:
+41.73743, -71.2893241°44'15" N, 71°17'22" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | RI 114/103 CNTY RD over WARREN RIVER |
Structure number: | 000000000001240 |
Location: | 0.1 Mi E of Barrington Rv |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 65.6 ft. [20.0 m] |
Total length: | 268.1 ft. [81.7 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 47.6 ft. [14.5 m] |
Owner: | State Highway Agency [01] |
Year built: | 1914 |
Year reconstructed: | 2009 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 4 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Box beam or girders - Multiple [05] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 19,999 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 71.3 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $11,681,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Fair | Good | Good | Satisfactory | 19999 | 71.3 |
May 2015 | Fair | Good | Good | Satisfactory | 19999 | 69.3 |
June 2013 | Fair | Good | Good | Satisfactory | 19900 | 68.0 |
June 2011 | Fair | Good | Good | Satisfactory | 23300 | 65.0 |
June 2009 | Good | Good | Good | Good | 23300 | 64.1 |
October 2002 | Poor | - | Fair | Poor | 18921 | 36.9 |
January 2001 | Poor | - | Fair | Poor | 18921 | 35.9 |
September 1998 | Poor | - | Fair | Poor | 18500 | 35.9 |
August 1996 | Poor | - | Fair | Poor | 21800 | 36.9 |
October 1995 | Poor | - | Fair | Poor | 10300 | 36.9 |
July 1994 | Poor | - | Fair | Poor | 10300 | 36.9 |
August 1992 | Poor | - | Fair | Poor | 17000 | 36.9 |
July 1990 | Poor | Satisfactory | Fair | Poor | 17000 | 35.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 2,894 | 2,829 | 65 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 10,520 | 10,520 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 8,046 | 8,046 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 143 | 20 | 123 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 95 | 47 | 47 | 1 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 150 | 150 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 60 | 0 | 60 | 0 | 0 |
Compression Joint | linear ft. | 35 | 35 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 104 | 100 | 4 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 1,151 | 1,143 | 8 | 0 | 0 |
Steel Protective Coating | sq. ft. | 5,755 | 5,755 | 0 | 0 | 0 |