Share:

S-1-111 over GOOSE CREEK

Map

Coordinates:
+34.40606, -82.31520
34°24'22" N, 82°18'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:S-1-111 over GOOSE CREEK
Structure number:000000000002443
Old structure number:000170011100100 (from 1992 edition)
Location:2.8MI NE DONALDS
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:15.1 ft. [4.6 m]
Total length:60.0 ft. [18.3 m]
Roadway width between curbs:26.2 ft. [8.0 m]
Deck width edge-to-edge:27.6 ft. [8.4 m]
Owner:State Highway Agency [01]
Year built:1957
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:225 [as of 2017]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:66.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairFairFairFair22566.1
October 2017FairFairFairFair22566.1
October 2016FairFairFairFair20066.2
October 2015FairFairFairFair20066.2
October 2014FairFairFairFair20066.2
October 2013FairFairFairFair22566.2
October 2012FairFairFairFair25066.2
October 2011FairFairFairFair32561.6
November 2010FairFairFairFair27561.7
September 2009FairFairFairFair25066.2
September 2008FairFairFairFair30061.7
October 2007FairFairFairFair42561.6
October 2006FairFairFairFair38061.6
October 2005FairFairFairFair30061.7
October 1999FairFairFairFair38061.8
September 1991FairGoodGoodSatisfactory13077.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Timber Pileeach2501906
Reinforced Concrete Pier Caplinear ft.138137100
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.120120000
Deck
Reinforced Concrete Slabsq. ft.1,6504001,25000