Share:

SC 125 over FURSE MILL CREEK

Map

Coordinates:
+33.09759, -81.52486
33°05'51" N, 81°31'29" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SC 125 over FURSE MILL CREEK
Structure number:000000000000316
Old structure number:000340012500100 (from 1992 edition)
Location:13MI W OF ALLENDALE
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:29.9 ft. [9.1 m]
Total length:50.9 ft. [15.5 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:47.2 ft. [14.4 m]
Owner:State Highway Agency [01]
Year built:1929
Year reconstructed:1975
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,850 [as of 2017]
Truck traffic:5% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present desirable criteria [8]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:78.8

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
May 2018Fair5 out of 10185078.8
May 2016Fair5 out of 10210076.7
May 2014Poor4 out of 10190064.2
June 2012Poor4 out of 10180064.2
July 2010Poor4 out of 10185064.2
July 2008Poor4 out of 10200064.2
July 2006Poor4 out of 10210064.2
July 2004Poor4 out of 10220064.2
June 1998Fair6 out of 10220090.5
June 1990Fair6 out of 10242988.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Prestressed Concrete Pileeach60600
Reinforced Concrete Pier Caplinear ft.7272000
Culvert
Reinforced Concrete Culvertlinear ft.14217821726
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.10299300
Deck
Reinforced Concrete Slabsq. ft.1,1991,199000