Share:

C-4-785 over BIG GENEROSTEE CR

Map

Coordinates:
+34.43395, -82.76157
34°26'02" N, 82°45'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:C-4-785 over BIG GENEROSTEE CR
Structure number:000000000004038
Old structure number:000490078500100 (from 1992 edition)
Location:7.8 MI SW OF ANDERSON
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:26.9 ft. [8.2 m]
Total length:51.8 ft. [15.8 m]
Roadway width between curbs:20.7 ft. [6.3 m]
Deck width edge-to-edge:22.6 ft. [6.9 m]
Owner:County Highway Agency [02]
Year built:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:126 [as of 2017]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:78.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactorySatisfactorySatisfactory12678.0
October 2015FairSatisfactorySatisfactorySatisfactory12678.0
October 2013FairSatisfactorySatisfactorySatisfactory12678.0
October 2011FairSatisfactorySatisfactorySatisfactory12678.0
November 2009FairSatisfactorySatisfactorySatisfactory12678.0
June 2008FairFairSatisfactorySatisfactory12677.0
June 2006FairFairSatisfactorySatisfactory13077.0
August 2004FairFairSatisfactorySatisfactory12077.0
July 1998FairSatisfactoryGoodGood6089.0
May 1990GoodGoodGoodGood6089.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.676676000
Substructure
Reinforced Concrete Pier Walllinear ft.2323000
Reinforced Concrete Abutmentlinear ft.6262000
Deck
Corrugated or Orthotropic Decksq. ft.1,1701,170000
Wearing Surfacessq. ft.1,04094001000
Steel Protective Coatingsq. ft.1,34501,34500
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.104104000