Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 21 NB over VILLAGE CREEK
Structure number:000000000001344
Old structure number:000720002100300 (from 1992 edition)
Location:7.8 MI SE BEAUFORT
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:9.8 ft. [3.0 m]
Total length:29.9 ft. [9.1 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:57.1 ft. [17.4 m]
Owner:State Highway Agency [01]
Year built:1947
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:6,000 [as of 2017]
Truck traffic:6% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:86.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
September 2018Fair5 out of 10600086.0
September 2016Fair5 out of 10570086.1
October 2014Fair5 out of 10430088.3
November 2012Fair5 out of 10430088.3
October 2010Fair5 out of 10460088.3
November 2008Good7 out of 10460099.4
November 2006Good7 out of 10570095.2
October 2004Good7 out of 10470096.3
July 1998Good7 out of 10530096.3
September 1990Good8 out of 10226696.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.1,710001,7100