Share:

SC 9 over CREWS BRANCH

Map

Coordinates:
+34.74249, -80.16789
34°44'33" N, 80°10'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SC 9 over CREWS BRANCH
Structure number:000000000000596
Old structure number:001340000900300 (from 1992 edition)
Location:0.8 MI E OF RUBY
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:9.8 ft. [3.0 m]
Total length:34.1 ft. [10.4 m]
Roadway width between curbs:41.0 ft. [12.5 m]
Deck width edge-to-edge:62.0 ft. [18.9 m]
Owner:State Highway Agency [01]
Year built:1932
Year reconstructed:1963
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:8,000 [as of 2017]
Truck traffic:6% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:84.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
November 2017Fair6 out of 10800084.0
November 2015Fair6 out of 10590084.2
November 2013Fair6 out of 10650084.2
November 2011Fair6 out of 10760087.7
December 2009Fair6 out of 10680087.8
November 2007Fair6 out of 10640087.8
November 2005Good7 out of 10780087.7
December 1999Good7 out of 10580087.3
October 1991Good8 out of 10577787.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.186186000