Share:

S-26-653 over SPRING SWAMP

Map

Coordinates:
+33.92182, -79.20603
33°55'19" N, 79°12'22" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:S-26-653 over SPRING SWAMP
Structure number:000000000006884
Old structure number:002670065300100 (from 1992 edition)
Location:6MI S AYNOR
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:15.1 ft. [4.6 m]
Total length:75.1 ft. [22.9 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:28.2 ft. [8.6 m]
Owner:State Highway Agency [01]
Year built:1976
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:300 [as of 2017]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:56.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairFairFairFair30056.7
August 2015FairFairFairFair30056.7
August 2013FairFairFairFair30056.7
July 2011FairFairFairFair30056.7
July 2009FairFairFairFair30056.7
August 2008FairFairFairFair30056.7
September 2007FairFairFairFair30056.7
August 2006FairFairFairFair30056.7
April 2005FairFairFairFair29056.7
May 1999FairFairFairFair54056.9
September 1991FairFairFairFair54056.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Timber Columneach3502807
Reinforced Concrete Pier Caplinear ft.196019600
Deck
Reinforced Concrete Slabsq. ft.2,115002,1150
Wearing Surfacessq. ft.2,1151,75536000