Share:

SC 9 over STREAM

Map

Coordinates:
+34.74233, -80.63486
34°44'32" N, 80°38'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SC 9 over STREAM
Structure number:000000000000349
Old structure number:002940000900800 (from 1992 edition)
Location:2.5 MI E OF LANCASTER
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:32.2 ft. [9.8 m]
Total length:32.2 ft. [9.8 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:35.8 ft. [10.9 m]
Owner:State Highway Agency [01]
Year built:1929
Year reconstructed:1940
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:6,100 [as of 2015]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:32.7 tons [29.7 metric tons]
Inventory rating:22.8 tons [20.7 metric tons]
Sufficiency rating:77.8
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$141,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201677.8FairSatisfactorySatisfactorySatisfactory-6100
September 201477.9FairSatisfactorySatisfactorySatisfactory-5800
August 201277.8FairSatisfactorySatisfactorySatisfactory-6500
September 201077.9FairSatisfactorySatisfactorySatisfactory-6000
August 200877.7FairSatisfactorySatisfactorySatisfactory-6700
August 200677.8FairSatisfactorySatisfactorySatisfactory-6100
August 200477.8FairSatisfactorySatisfactorySatisfactory-6300
August 199870.9FairSatisfactorySatisfactorySatisfactoryFO6500
May 199073.1FairSatisfactorySatisfactorySatisfactory-4260