Share:

I029 S over 186A ST, HIDEWOOD CK

Map

Coordinates:
+44.67914, -96.83083
44°40'45" N, 96°49'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I029 S over 186A ST, HIDEWOOD CK
Structure number:000000020027207
Location:5.5 SE SD 22 INTERCH
Purpose:Carries highway over highway and waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:94.2 ft. [28.7 m]
Total length:233.0 ft. [71.0 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:40.7 ft. [12.4 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,842 [as of 2017]
Truck traffic:20% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Superior to present desirable criteria [9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Sufficiency rating:95.8

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairSatisfactorySatisfactorySatisfactory384295.8
April 2015FairGoodSatisfactoryGood357095.8
April 2013FairGoodSatisfactoryGood338095.8
May 2011FairGoodSatisfactoryGood384595.3
April 2009FairGoodSatisfactoryGood365093.3
April 2007FairGoodSatisfactoryGood368093.3
March 2005FairGoodSatisfactoryGood339593.1
May 2003FairSatisfactorySatisfactoryGood322593.1
June 2001FairSatisfactoryFairGood274082.7
August 1999GoodGoodGoodGood291593.7
July 1999FairSatisfactorySatisfactoryGood305593.7
November 1997GoodGoodGoodGood284593.7
August 1995GoodGoodGoodGood275593.8
August 1993GoodGoodGoodGood214397.8
August 1991GoodGoodGoodGood259097.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,1531,0787500
Steel Protective Coatingsq. ft.15,0007,0006,960520520
Deck
Reinforced Concrete Decksq. ft.9,47709,47700
Wearing Surfacessq. ft.17,70815,7301,97800
Substructure
Reinforced Concrete Columneach65100
Reinforced Concrete Abutmentlinear ft.114803400
Reinforced Concrete Pier Caplinear ft.80532700
Joints
Strip Seal Jointlinear ft.82453070
Bearings
Fixed Bearingeach1010000
Steel Protective Coatingsq. ft.1001000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.46615531100