353RD AVE over SOUTH FORK SNAKE CK
Map
Coordinates:
+45.04243, -99.1242145°02'33" N, 99°07'27" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | 353RD AVE over SOUTH FORK SNAKE CK |
Structure number: | 000000025220138 |
Location: | 0.5N FAULKTON |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 35.1 ft. [10.7 m] |
Total length: | 163.1 ft. [49.7 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 28.2 ft. [8.6 m] |
Owner: | County Highway Agency [02] |
Year built: | 1952 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 13.5 / HS 15 [3] |
Number of main spans: | 5 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, posting recommended but not legally implemented [B] |
Average daily traffic: | 402 [as of 2016] |
Truck traffic: | 3% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 67.1 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Satisfactory | Satisfactory | Good | 402 | 67.1 |
September 2016 | Fair | Satisfactory | Satisfactory | Good | 402 | 67.1 |
October 2014 | Fair | Satisfactory | Satisfactory | Good | 402 | 67.1 |
October 2012 | Fair | Satisfactory | Satisfactory | Good | 402 | 69.5 |
September 2010 | Fair | Satisfactory | Satisfactory | Good | 402 | 69.5 |
August 2008 | Fair | Satisfactory | Satisfactory | Good | 402 | 69.5 |
August 2006 | Fair | Satisfactory | Satisfactory | Good | 402 | 69.5 |
May 2004 | Good | Good | Good | Good | 402 | 69.5 |
August 2002 | Good | Good | Good | Good | 402 | 69.5 |
August 2000 | Good | Good | Good | Good | 402 | 69.5 |
September 1998 | Good | Good | Good | Good | 402 | 69.5 |
July 1996 | Good | Very Good | Very Good | Very Good | 402 | 74.2 |
August 1994 | Good | Very Good | Very Good | Very Good | 402 | 72.9 |
August 1992 | Good | Very Good | Very Good | Very Good | 402 | 72.9 |
August 1990 | Good | Very Good | Very Good | Very Good | 402 | 72.9 |