Share:

360TH AVE over CK

Map

Coordinates:
+45.17461, -98.98083
45°10'29" N, 98°58'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:360TH AVE over CK
Structure number:000000025290048
Location:1.5W & 0.2N CRESBARD
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:9.8 ft. [3.0 m]
Total length:20.7 ft. [6.3 m]
Roadway width between curbs:20.7 ft. [6.3 m]
Deck width edge-to-edge:22.3 ft. [6.8 m]
Owner:County Highway Agency [02]
Year built:1938
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:60 [as of 2016]
Truck traffic:2% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:80.1

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
September 2018Fair6 out of 106080.1
September 2016Good7 out of 106080.1
October 2014Good7 out of 106080.1
October 2012Good7 out of 106080.1
September 2010Good7 out of 106080.1
August 2008Good7 out of 106080.1
August 2006Good7 out of 106080.1
June 2004Good7 out of 106080.1
September 2002Good7 out of 106080.1
August 2000Good8 out of 106080.1
September 1998Good8 out of 106080.1
July 1996Fair6 out of 106088.8
August 1994Fair6 out of 106088.5
August 1992Fair6 out of 106089.5
August 1990Fair6 out of 106089.5