184th Street over Stray Horse Creek
Map
Coordinates:
+44.71734, -96.9734844°43'02" N, 96°58'25" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | 184th Street over Stray Horse Creek |
Structure number: | 000000029256060 |
Location: | 2.6E & 1S of Castlewood |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 89.9 ft. [27.4 m] |
Total length: | 91.9 ft. [28.0 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 32.8 ft. [10.0 m] |
Owner: | County Highway Agency [02] |
Year built: | 1990 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: June 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 376 [as of 2016] |
Truck traffic: | 2% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 97.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2018 | Good | Good | Very Good | Good | 376 | 97.7 |
June 2016 | Good | Good | Very Good | Good | 376 | 99.9 |
May 2014 | Fair | Satisfactory | Very Good | Good | 376 | 99.9 |
June 2012 | Fair | Satisfactory | Very Good | Good | 376 | 99.9 |
August 2010 | Fair | Satisfactory | Very Good | Good | 376 | 99.9 |
September 2008 | Fair | Fair | Very Good | Good | 376 | 98.9 |
August 2006 | Good | Good | Very Good | Good | 376 | 99.9 |
July 2004 | Good | Good | Very Good | Good | 376 | 99.9 |
August 2002 | Good | Good | Very Good | Good | 376 | 99.9 |
July 2000 | Good | Good | Very Good | Good | 376 | 99.9 |
September 1998 | Good | Good | Very Good | Good | 376 | 99.9 |
August 1996 | Good | Very Good | Good | Excellent | 376 | 99.9 |
August 1994 | Good | Very Good | Good | Excellent | 376 | 99.9 |
June 1992 | Good | Excellent | Excellent | Excellent | 376 | 99.9 |
August 1990 | Good | Excellent | Excellent | Excellent | 376 | 99.9 |