I090 E over 173 AVE (FAS 6110)
Map
Coordinates:
+44.10327, -102.5881844°06'12" N, 102°35'17" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I090 E over 173 AVE (FAS 6110) |
Structure number: | 000000052730286 |
Location: | 8 W WASTA INTERCHANGE |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 55.1 ft. [16.8 m] |
Total length: | 158.1 ft. [48.2 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 34.5 ft. [10.5 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1960 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: July 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,040 [as of 2017] |
Truck traffic: | 23% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 58.4 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $780,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2017 | Fair | Fair | Fair | Satisfactory | 4040 | 58.4 |
July 2015 | Fair | Good | Satisfactory | Satisfactory | 3650 | 70.5 |
July 2013 | Fair | Good | Satisfactory | Satisfactory | 3600 | 70.5 |
July 2011 | Fair | Good | Satisfactory | Satisfactory | 3785 | 70.5 |
July 2009 | Fair | Fair | Satisfactory | Satisfactory | 3695 | 69.5 |
July 2007 | Fair | Fair | Satisfactory | Satisfactory | 3650 | 69.5 |
September 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 3410 | 70.2 |
September 2003 | Fair | Good | Good | Satisfactory | 3640 | 70.2 |
July 2002 | Fair | Good | Good | Satisfactory | 3810 | 70.2 |
November 2000 | Fair | Satisfactory | Good | Satisfactory | 3550 | 69.3 |
November 1998 | Fair | Fair | Satisfactory | Satisfactory | 3685 | 69.3 |
November 1996 | Fair | Good | Satisfactory | Satisfactory | 4050 | 71.2 |
November 1994 | Fair | Good | Satisfactory | Satisfactory | 3730 | 71.1 |
November 1992 | Fair | Good | Satisfactory | Satisfactory | 2100 | 72.5 |
November 1990 | Fair | Good | Satisfactory | Good | 3165 | 66.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Substructure |
Reinforced Concrete Column | each | 2 | 0 | 2 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 100 | 74 | 26 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 69 | 69 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 64 | 64 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 316 | 235 | 81 | 0 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 5,425 | 2,861 | 2,544 | 20 | 0 |
Wearing Surfaces | sq. ft. | 9,480 | 8,199 | 1,263 | 0 | 18 |