Share:

IRR US012 over MISSOURI RV (OAHE LK)

Map

Coordinates:
+45.56114, -100.46131
45°33'40" N, 100°27'41" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IRR US012 over MISSOURI RV (OAHE LK)
Structure number:000000065000020
Location:CORSON - WALWORTH CO LN
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:449.8 ft. [137.1 m]
Total length:5058.6 ft. [1541.8 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:28.5 ft. [8.7 m]
Vertical clearance above deck:17.4 ft. [5.3 m]
Vertical clearance below bridge:39.4 ft. [12.0 m]
Owner:State Highway Agency [01]
Year built:1959
Year reconstructed:1980
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,076 [as of 2017]
Truck traffic:11% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:44.6
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$25,000,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018FairSatisfactoryFairFair207644.6
September 2017FairSatisfactoryFairFair207644.6
September 2016FairSatisfactoryFairFair212744.6
September 2015FairSatisfactoryFairFair225944.6
September 2014FairSatisfactoryFairFair220044.6
September 2013FairSatisfactoryFairFair227644.6
September 2012FairSatisfactoryFairFair165646.6
September 2011FairGoodFairFair165646.6
October 2010FairGoodFairFair164827.6
September 2009FairSatisfactoryFairFair165627.6
September 2008FairSatisfactoryFairFair158527.6
September 2007FairSatisfactoryFairFair167527.6
September 2006FairSatisfactoryFairFair254525.6
September 2005FairSatisfactoryFairFair254525.6
September 2004FairSatisfactoryFairFair254425.6
October 2003FairGoodFairFair258825.6
September 2002FairGoodFairFair267625.6
May 2001FairGoodFairGood276625.5
June 2000FairGoodFairGood286025.5
May 1999FairGoodFairGood293925.5
June 1997FairGoodSatisfactorySatisfactory320635.5
July 1996FairGoodSatisfactorySatisfactory354035.5
July 1995FairGoodSatisfactorySatisfactory330533.3
July 1994FairGoodSatisfactorySatisfactory295531.4
October 1992FairGoodSatisfactorySatisfactory199033.4
November 1991FairGoodSatisfactorySatisfactory206031.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.5,9145,239664110
Steel Protective Coatingsq. ft.144,530144,381130136
Steel Stringerlinear ft.25,29325,14115020
Steel Protective Coatingsq. ft.116,178116,09639043
Deck
Reinforced Concrete Decksq. ft.145,027144,889120180
Wearing Surfacessq. ft.145,027142,8832,100044
Superstructure
Steel Trusslinear ft.4,2033,5203773060
Steel Protective Coatingsq. ft.185,590185,51515060
Steel Floor Beamlinear ft.6,7396,1714531150
Steel Protective Coatingsq. ft.34,62434,53624064
Steel Pin or Pin & Hangar Assemblyeach48262200
Steel Protective Coatingsq. ft.1,2001,196004
Steel Gusset Plateeach33618459930
Steel Protective Coatingsq. ft.8,7308,68520025
Substructure
Reinforced Concrete Columneach44212210
Reinforced Concrete Abutmentlinear ft.1361201600
Reinforced Concrete Pile Cap/Footinglinear ft.8507638700
Steel Pileeach7207200
Reinforced Concrete Pier Caplinear ft.55447753240
Joints
Strip Seal Jointlinear ft.28725261415
Compression Jointlinear ft.6305508000
Open Jointlinear ft.5757000
Bearings
Movable Bearingeach4003640
Steel Protective Coatingsq. ft.1,5101,4832025
Fixed Bearingeach2002000
Steel Protective Coatingsq. ft.7827594019
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4444000
Steel Protective Coatingsq. ft.118118000
Reinforced Concrete Bridge Raillinear ft.10,1177,5122,2223830