Share:

NFA A028 over POPLAR COVE CREEK

Map

Coordinates:
+36.44830, -84.99850
36°26'54" N, 84°59'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NFA A028 over POPLAR COVE CREEK
Structure number:250A0280001
Location:.5 MI NORTH OF SR 52
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:12.1 ft. [3.7 m]
Total length:39.0 ft. [11.9 m]
Roadway width between curbs:22.3 ft. [6.8 m]
Deck width edge-to-edge:25.9 ft. [7.9 m]
Owner:County Highway Agency [02]
Year built:1986
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:60 [as of 2017]
Truck traffic:4% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:99.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
August 2016Good7 out of 106099.0
August 2014Good7 out of 106099.0
August 2012Good7 out of 106099.0
July 2010Good7 out of 106099.0
July 2008Good7 out of 106099.0
July 2006Good7 out of 106099.0
September 2004Good7 out of 106099.0
August 2002Good7 out of 106099.0
August 2000Good7 out of 106099.0
July 1998Good7 out of 106099.0
June 1996Good7 out of 105097.0
June 1994Good7 out of 105097.0
July 1992Good7 out of 105097.0
June 1990Good7 out of 105097.0