Share:

NFA 936 (SA 2812) over BRANCH

Map

Coordinates:
+35.26437, -87.18868
35°15'52" N, 87°11'19" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NFA 936 (SA 2812) over BRANCH
Structure number:28F00140007
Location:8.5 M. NW. PULASKI.
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:13.1 ft. [4.0 m]
Total length:27.9 ft. [8.5 m]
Roadway width between curbs:20.3 ft. [6.2 m]
Deck width edge-to-edge:22.3 ft. [6.8 m]
Owner:County Highway Agency [02]
Year built:1960
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:840 [as of 2018]
Truck traffic:10% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:71.3
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$121,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
February 2018Fair6 out of 1084071.3
February 2016Fair6 out of 1084072.6
February 2014Fair6 out of 1084072.6
February 2012Fair6 out of 1084072.6
March 2010Fair6 out of 1084072.6
March 2008Fair6 out of 1084069.6
February 2006Fair6 out of 1080069.6
March 2004Fair6 out of 1092069.5
March 2002Fair6 out of 1082069.6
March 2000Fair6 out of 10116068.2
March 1998Fair6 out of 1036071.1
June 1996Fair6 out of 10117066.2
June 1993Fair6 out of 10122067.1
July 1991Fair6 out of 1096067.4